Chromatography Fittings
- (1)
- (23)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (1)
- (3)
- (1)
- (1)
- (3)
- (1)
- (1)
- (2)
- (5)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (34)
- (2)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (4)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (8)
- (21)
- (1)
- (4)
- (10)
- (5)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (4)
- (2)
- (1)
- (19)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (4)
- (4)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (3)
- (1)
- (1)
- (2)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (8)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (3)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (20)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (4)
- (6)
- (1)
- (2)
- (1)
- (1)
- (1)
- (5)
- (1)
- (1)
- (1)
- (1)
- (12)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (10)
- (14)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (6)
- (1)
- (3)
- (34)
- (4)
- (1)
- (1)
- (2)
- (1)
- (2)
- (3)
- (1)
- (11)
- (4)
- (8)
- (1)
- (3)
- (5)
- (57)
- (1)
- (1)
- (33)
- (1)
- (1)
- (1)
- (3)
- (2)
- (1)
- (1)
- (8)
- (1)
- (10)
- (1)
- (1)
- (2)
- (1)
- (2)
- (2)
- (1)
- (8)
- (108)
- (1)
- (1)
- (6)
- (1)
- (1)
- (6)
- (4)
- (2)
- (3)
- (2)
- (15)
- (1)
- (11)
- (1)
- (1)
- (1)
- (5)
- (1)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (16)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (4)
- (2)
- (7)
- (1)
- (1)
- (1)
- (3)
- (3)
- (1)
- (1)
- (1)
Filtered Search Results
Optimize Technologies EXP Trap Cartridge, 3.0mm x 5mm, 2.7µm HALO, Phenyl-Hexyl, 3pk
The Hand-Tight EXP™ Trap Column is rated to 20,000+ psi. This unique design connects directly to any injection valve (with 10-32 threads) or in-line with 1/16” tubing for unparalleled convenience and efficiency. The EXP™ System enables chemists to quickly remove detergents or salts which can affect the ionization process in MS work. This trapping technique can concentrate the sample directly on-line, allowing for increased recovery of precious sample material compared to off-line techniques. Free-Turn™ architecture allows users to change cartridges by hand without breaking fluid connections on the holder inlet/outlet. The EXP™ Trap Column family now offers packed beds available in 2, 5, 10, 15, 20 and 30mm lengths with diameters ranging from 1-4.6mm and bed volumes from 1.6-600µL. Please contact your representative directly if you're interested in a length other than 5mm.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies OPTI-MAX EXP Single Ball Upgrade for UHPLC Pressures, 1/8" Single Ceramic Ball & Seat, SS Replacement Cartridge with PEEK endcaps, Fits all OPTI-MAX Housings (except xx-6x-xxxxx) 2pk
Opti-Max Check Valves are manufactured with ball and seat sets that are individually matched to ensure a lock-and-key fit. This guarantees 3 bubbles per minute or less in the standard nitrogen bubble test. Optimize has also minimized the ball travel distance within the check valve which results in quicker seating and more accurate pump metering. A single OPTI-MAX cartridge is interchangeable across multiple pump brands, and will function in either the inlet or outlet position. The same replacement cartridge will fit into OPTI-MAX housings for pumps made by Waters, Shimadzu, Agilent/HP, and most other OEM solvent delivery systems. This allows you to minimize the number of spare check valve cartridges you keep on hand, and dramatically reduce the cost of inventory required to cover your maintenance needs. This particular check valve is recommended for acetonitrile applications. Please contact your Fisher or Optimize representative to view a full list of OPTI-MAX cartridges.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP Trap Cartridge, 4.6mm x 5mm, 2.7µm HALO, C8, 3pk
The Hand-Tight EXP™ Trap Column is rated to 20,000+ psi. This unique design connects directly to any injection valve (with 10-32 threads) or in-line with 1/16” tubing for unparalleled convenience and efficiency. The EXP™ System enables chemists to quickly remove detergents or salts which can affect the ionization process in MS work. This trapping technique can concentrate the sample directly on-line, allowing for increased recovery of precious sample material compared to off-line techniques. Free-Turn™ architecture allows users to change cartridges by hand without breaking fluid connections on the holder inlet/outlet. The EXP™ Trap Column family now offers packed beds available in 2, 5, 10, 15, 20 and 30mm lengths with diameters ranging from 1-4.6mm and bed volumes from 1.6-600µL. Please contact your representative directly if you're interested in a length other than 5mm.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Trajan Scientific HPLC Kit MyCapLC Medical 3/PK
MyCapLC kit containing components to assemble three complete 1/16 OD x 530 m ID x 150 mm length UHPLC columns with 250 mm inlet and 100 mm outlet tails 1/32 OD x 50 m ID
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP Trap Cartridge, 3.0mm x 5mm, 2.7µm HALO, C8, 3pk
The Hand-Tight EXP™ Trap Column is rated to 20,000+ psi. This unique design connects directly to any injection valve (with 10-32 threads) or in-line with 1/16” tubing for unparalleled convenience and efficiency. The EXP™ System enables chemists to quickly remove detergents or salts which can affect the ionization process in MS work. This trapping technique can concentrate the sample directly on-line, allowing for increased recovery of precious sample material compared to off-line techniques. Free-Turn™ architecture allows users to change cartridges by hand without breaking fluid connections on the holder inlet/outlet. The EXP™ Trap Column family now offers packed beds available in 2, 5, 10, 15, 20 and 30mm lengths with diameters ranging from 1-4.6mm and bed volumes from 1.6-600µL. Please contact your representative directly if you're interested in a length other than 5mm.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP™ Trap Cartridge, 2.1mm x 5mm, 5.0µm HALO, C18, 3pk
The Hand-Tight EXP™ Trap Column is rated to 20,000+ psi. This unique design connects directly to any injection valve (with 10-32 threads) or in-line with 1/16” tubing for unparalleled convenience and efficiency. The EXP™ System enables chemists to quickly remove detergents or salts which can affect the ionization process in MS work. This trapping technique can concentrate the sample directly on-line, allowing for increased recovery of precious sample material compared to off-line techniques. Free-Turn™ architecture allows users to change cartridges by hand without breaking fluid connections on the holder inlet/outlet. The EXP™ Trap Column family now offers packed beds available in 2, 5, 10, 15, 20 and 30mm lengths with diameters ranging from 1-4.6mm and bed volumes from 1.6-600µL. Please contact your representative directly if you're interested in a length other than 5mm.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP™2 Replacement Stems, 1.5µL, 5.0µm HALO, C8 3pk
Specialized features, patented technology, precision engineering and state-of-the-art manufacturing make the new EXP2 Stem Trap an unbeatable choice for ultra high-pressure trapping applications. Its slim architecture allows it to easily fit into crowded instrument compartments or to connect directly to tightly-spaced injection ports. When tightened by hand, the EXP2 Stem Trap seals to 8,700+ psi. Additionally, the product can be wrench tightened to 20,000+ psi (1,400+ bar). The unique packed floating stem installs directly into any 10-32 port and automatically adjusts to provide a perfect ZDV connection. The new EXP2 design incorporates an integral ferrule into the front-end of the holder so there is no separate ferrule to lose! The replacement stems are also low volume/ low-dispersion, intended for many repeat uses and is available with various bed volume and custom packing options. This product is recommended for nano flow applications. For use with EXP™2 Stem Holder Only
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Trajan Scientific PEEK FINGERTITE FITTING 1/32" TO 10-32 UNF (LONG) PK10
PEEK FINGERTITE FITTING 1/32" TO 10-32 UNF (LONG) PK10
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mac-Mod PEEK Column Coupler for All-Guard Cartridge Holder (standard column port)
The PEEK one-piece fingertight column coupler is ideal for connecting two analytical columns or analytical columns to guard columns or cartridges. Ultra low dead volume. Inert and biocompatible. Withstands pressure up to 6000 psi. Female-female connector.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
eMolecules 13161-30-3 | 2-hydroxy-1??-pyridin-1-one | Pharmablock111.100 | C5H5NO2 | 97.000 | Oc1ccccn1=O | 25mg | 680111544
2-hydroxy-1??-pyridin-1-one | Pharmablock | 13161-30-3111.100 | C5H5NO2 | 97.000 | Oc1ccccn1=O | 25mg | 680111544
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP™2 Filter Cartridge, 3mm, 2µm, 10/pk
The EXP™2 Pre-Column and In-Line Hand-Tight Filters are ideal for protecting small-particle UHPLC columns and systems at extreme pressures. Such techniques analyze samples in the most demanding applications, decreasing the life of expensive hardware. EXP™2 Filters help extend the life of a UHPLC system and protect your investment without sacrificing performance. Free-Turn™ architecture allows the user to change cartridges by hand without breaking fluid connections on the holder inlet/outlet. EXP™2 Pre-Column Filter holders are available with Titanium Hybrid Ferrules for easy direct connection to any 10-32 port. The filter holder is a complete package and includes fittings to provide repeated zero-dead-volume connections. Use with holder part number 15-04-05242 or 15-04-05258.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP Trap Cartridge, 2.1mm x 5mm, 2.7µm HALO, HILIC, 3pk
The Hand-Tight EXP™ Trap Column is rated to 20,000+ psi. This unique design connects directly to any injection valve (with 10-32 threads) or in-line with 1/16” tubing for unparalleled convenience and efficiency. The EXP™ System enables chemists to quickly remove detergents or salts which can affect the ionization process in MS work. This trapping technique can concentrate the sample directly on-line, allowing for increased recovery of precious sample material compared to off-line techniques. Free-Turn™ architecture allows users to change cartridges by hand without breaking fluid connections on the holder inlet/outlet. The EXP™ Trap Column family now offers packed beds available in 2, 5, 10, 15, 20 and 30mm lengths with diameters ranging from 1-4.6mm and bed volumes from 1.6-600µL. Please contact your representative directly if you're interested in a length other than 5mm.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies OPTI-LYNX™ Trap Cartridges, 10µL Bed, Cyano/40µm, 5pk
OPTI-LYNX™ Trap Cartridges combine the convenience of our quick-connect holder with a versatile selection of packed-bed cartridges to offer chromatographers numerous options for on-line or off-line sample clean-up and pre-concentration. Each cartridge shares the same external dimensions, allowing you to use different diameters and porosities with the same holder hardware. OPTI-LYNX™ Traps are available in packed-bed volumes of 4 µL to 100 µL with a wide range of standard and custom packings. Whether you want to separate a peptide digest from its matrix for further analyses, or prepare a dilute small molecule sample for LC injection without any sample loss - OPTI-LYNX™ Traps are the ideal tool to optimize your technique. These columns can be loaded and regenerated repeatedly for maximum value.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP™2 6-40 Fitting Kit for 1/32" OD SS Tubing (10 Titanium Hybrid Ferrules, 10 EXP™2 Nuts & 1 EXP™2 Driver)
Featuring a small 3/16” hex-head EXP™2 nut, EXP™ Original Titanium Hybrid Ferrule and the new EXP™2 Driver, the EXP™2 Fittings offer hand-tight connections rated to 20,000 psi+. The EXP™2 Nuts are available with 6-32, 6-40 and 10-32 threads and have been scaled down to allow for maximum working room in cramped spaces. The EXP™2 Driver is a small, easy to use knurled torque driver which snaps on to the nuts for hand-tightening and loosening. It is also slotted so that it can be easily removed from the nut and tubing after use. The Hybrid Ferrule provides a perfect seal with every connection, yet the swage can be released without tools to adjust to the different port depths of various hardware. This adjustability provides unlimited value through repeated zero-dead-volume connections with any port configuration. EXP™2 fittings are the premier adjustable nut and ferrule compression system for extreme high-pressure connections.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Optimize Technologies EXP™ Analytical Column Direct-Connect Holder Kit, 100mm
The cartridge-based EXP™ Analytical Column System is designed for superior chromatographic analysis with each injection rated for routine use up to 20,000 psi. The EXP™ Analytical Column Holders incorporate Free-Turn™ architecture allowing the user to quickly exchange columns by hand without breaking any fluid connections. The holders are available in two formats: In-Line and Direct Connect, allowing the user to bypass additional tubing and connect directly to the detector for even greater resolution. Holder kits include EXP™ Nuts and Titanium Hybrid Ferrules to ensure repeated zero-dead-volume connections. EXP™ Analytical Column Hardware is available for purchase as empty columns. The column hardware is assembled up to the point of packing, allowing the customer to completely control the resins used, packing processes and testing conditions. Packing fixtures are also available and are compatible with all column dimensions.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More